Vivado の WARNING: [Labtools 27-3222] の解決法

Last updated at Posted at 2021-09-08

#エラー

WARNING: [Labtools 27-3222] Mismatch between the design programmed into the device xc7z020 (JTAG device index = 1) and the probes file(s)
/....../[Project name]/[Project name].runs/impl_1/design_1_wrapper.ltx.
The hw_probe in the probes file has port index 6. This port does not exist in the ILA core at location (uuid_23E7D65A79BC59F7BC47406C1714DFAE).

と表示され、Waveformが表示されない

#解決法
左のペインのHardware->Xilinxのコアを右クリックしてProgram deviceでFPGAをプログラムする。

(あまりに初歩的なミスなのでネットのどこにも転がっていませんでした。同じようなミスをした人が困らないように恥を忍んで残しておきます。)