  1. Introduction
    The Burcam Grinder Pump 400700 is designed for residential and light commercial sewage applications. This guide will provide information on the installation, operation, and maintenance of the grinder pump.

  2. Safety Instructions
    Read all instructions before operating the grinder pump.
    Electrical Safety: Ensure the power supply is disconnected before installing or servicing the pump.
    Installation Compliance: Follow local electrical and plumbing codes.
    Avoid hazards: Do not use the pump for applications other than those intended.

  3. Specifications
    Model Number: 400700
    Horsepower: 3/4 HP
    Voltage: 115V / 230V
    Frequency: 60 Hz
    Discharge Size: 1-1/4 inch NPT
    Max Flow Rate: 50 GPM
    Max Head: 50 feet

  4. Installation Instructions
    A. Tools and Materials Required
    Pipe wrench
    Screwdriver
    PVC piping and fittings
    Pipe sealant
    B. Installation Steps
    Positioning: Place the pump in the sump basin. Ensure it is stable and level.
    Piping:
    Connect the discharge pipe to the pump outlet.
    Install a check valve in the discharge line to prevent backflow.
    Use pipe sealant on all threaded connections to prevent leaks.
    Electrical Connection:
    Ensure the power supply matches the pump’s voltage rating.
    Connect the pump to a grounded outlet or hardwire according to local codes.
    Install a dedicated circuit breaker for the pump.
    Ventilation: Ensure the sump basin is properly vented to avoid gas buildup.
    Testing:
    Fill the sump basin with water.
    Turn on the power and observe the pump operation.
    Check for leaks and proper discharge.

  5. Operation
    The grinder pump operates automatically with a float switch that activates the pump when the water level rises.
    Regularly inspect the pump and basin to ensure proper operation.
    Avoid disposing of materials that can damage the pump such as diapers, rags, or large solid objects.

  6. Maintenance
    Monthly: Inspect the pump for debris and clean if necessary.
    Annually: Have a professional check the pump and electrical connections.
    Troubleshooting
    Pump not starting: Check the power supply and float switch operation.
    Reduced flow: Inspect the discharge pipe and check valve for blockages.
    Pump runs continuously: Verify float switch is not obstructed and check for leaks in the discharge line.
    This guide should help you with the basic installation, operation, and maintenance of your Burcam Grinder Pump 400700. For detailed technical support, always refer to the official manual provided with your unit or visit the manufacturer’s website.

0
0
0

Register as a new user and use Qiita more conveniently

  1. You get articles that match your needs
  2. You can efficiently read back useful information
  3. You can use dark theme
What you can do with signing up
0
0

Delete article

Deleted articles cannot be recovered.

Draft of this article would be also deleted.

Are you sure you want to delete this article?